Tel: +86-13910814865
Email: bjyuanhuatc@gmail.com
Calibrating at high pressure is usually the slowest job in the workshop. A hand pump or a screw press has to be worked up to the set point, held by hand while the reading settles, and repeated for every point on the certificate. The TC618B fully automatic pressure calibrator takes that sequence out of the operator’s hands and puts it on the touchscreen.
You enter the target and the unit raises pressure through a high-precision control valve on a servo-driven loop, stops at the set point and holds it while the reading stabilises. Because the same loop controls both pressure and rate of change, the approach is fast without overshooting — which matters on a 60 MPa hydraulic system where an overshoot can damage the instrument under test.
The working medium is transformer oil or purified water, chosen to match the system being tested, and the pressure module can be fitted inside the case or connected externally. That is what keeps the TC618B fully automatic pressure calibrator usable as range requirements grow: a new range means a new module, not a new instrument.
Electrical work is covered in the same visit. Current, voltage, a 24 V DC output and switch detection are built in, and HART pressure transmitters can be calibrated without a separate communicator. Results are stored and exported, so the certificate comes out of the same run that produced the pressure readings.
The table below lists the TC618B fully automatic pressure calibrator as supplied. Range is the one item that changes between orders; the housing, display and control system are common to every unit.
| Parameter | Portable hydraulic unit — specification |
|---|---|
| Pressure range | (0 ~ 60) MPa |
| Pressure stability | 0.005% F.S |
| Pressure module | Matched as required; built-in or external |
| Working medium | Transformer oil or purified water |
| Pressure interface | 2 × M20×1.5, with connection for an external pressure converter |
| Display | 7-inch high-definition colour touchscreen |
| Enclosure | PP safety case with internal steel lining |
| Power | Built-in high-capacity rechargeable battery |
| Pressure units | Pa, kPa, hPa, MPa, psi, bar, mbar, inH₂O, mmH₂O, inHg, mmHg, kgf/cm² |
| Protection | Overpressure alarm at 120% of range; sensor fault alarm |
Measurement resolution is selectable at 4, 5 or 6 digits. Interface thread adaptors for other connection standards are quoted with the order. Verification points, soak times and certificate output are covered in the TC618B operating guide.
| Function | Range | Accuracy |
|---|---|---|
| Current | (−30 ~ 30) mA, resolution 0.1 µA | ± (0.01% RD + 0.005% FS) |
| Voltage | (−30 ~ 30) V, resolution 0.1 mV | ± (0.01% RD + 0.005% FS) |
| DC output | 24 V, load 50 mA, overload protection 120 mA, ± 0.5 V | — |
| Switch | On / off detection | Response < 12 ms |
The electrical channels on the TC618B fully automatic pressure calibrator run independently of the pressure loop, so a transmitter can be checked on both sides at once: applied pressure on one screen, output current on the other.
| TC618B — hydraulic | TC618A — air | |
|---|---|---|
| Working medium | Transformer oil or purified water | Air (vacuum / pneumatic) |
| Pressure range | (0 ~ 60) MPa | (−50 ~ 50 / 100 / 250) kPa and (−0.095 ~ 4 / 7 / 10 / 15) MPa |
| Pressure stability | 0.005% F.S | ≤ 0.003% FS |
| Suits | High-pressure hydraulic gauges, transmitters and switches on liquid-filled systems | Low-pressure, vacuum and dry systems: draft gauges, pneumatic transmitters, leak test rigs |
| Cleanliness | Fluid has to be handled and purged after use | No fluid; nothing to drain or clean |
| Portability | Case-mounted; the fluid handling is the extra step | Case-mounted; ready to use as carried |
Working above roughly 1 MPa on a liquid-filled system — hydraulic is the only option. Air cannot reach 60 MPa, and a liquid system should be tested with liquid.
Working in kilopascals, or pulling a vacuum — the TC618A air-pressure calibrator covers ranges this unit cannot reach, and leaves no oil to purge afterwards.
Narrow, low-pressure work with a dry instrument — introducing oil creates a cleaning job that did not exist before.
Sites that calibrate both ends of the scale usually keep one of each rather than choosing. Where a single purchase has to cover the whole plant, specify the TC618B fully automatic pressure calibrator for the high-pressure work and add a micro-pressure module for the low end.
Tell us the instruments you calibrate and the pressure range you work in. We reply with a matched configuration, lead time and price — usually within one business day.
Pressure range, medium and quantity help us quote faster.