The TC698A calibration system is a modular pressure calibration platform: five pressure generators — vacuum, micro-pressure, pneumatic, hydraulic oil and water — driven by one controller, held to one stability criterion and recorded in one format.
A vacuum pump pulling to −0.095 MPa and a hydraulic pressuriser reaching 160 MPa cannot share a cylinder, and this platform does not try to make them. What the five units do share is the part that decides whether two calibrations can be compared at all: the controller that sets the point, waits for it to stop moving, and records what the instrument said.
Accuracy class and pressure units are fixed at configuration on every TC698A calibration system, so the figure that counts sits on the drawing rather than in the catalogue headline.
| Accuracy class | 0.01 / 0.02 / 0.05 % F.S., selected per configuration |
|---|---|
| Pressure stability | Better than 0.003% F.S. on the vacuum unit; better than 0.005% F.S. on the other units |
| Pressure control | Dual closed loop — pressure and pressure-change rate |
| Single-point stabilisation | Approx. 10 s (vacuum unit); 10–15 s (other units), depending on unit and conditions |
| Display | 10-inch colour touchscreen; 4 / 5 / 6 / 7 digit resolution |
| Pressure units on display | Pa, kPa, hPa, MPa, psi, bar, mbar, inH₂O, mmH₂O, inHg, mmHg, kgf/cm² |
| Configuration | 2-in-1 / 3-in-1 / 4-in-1 / 5-in-1 / custom |
| Communication | Wireless, Wi-Fi, Bluetooth, LAN, RS232/485, USB |
| Industrial protocols | HART, PROFIBUS PA — configuration dependent |
| Protection | Overpressure, incorrect connection, pressure sensor fault alarm, pressure control monitoring |
Accuracy class and pressure units are fixed at configuration on every TC698A calibration system, so the figure that counts sits on the drawing rather than in the catalogue headline.
A transmitter is calibrated on two numbers at once — the pressure it was given, and the signal it sent back. Reading the second on a separate meter and typing it in afterwards is where most of the avoidable error in a calibration certificate enters.
| DC current | Measurement of 4–20 mA transmitter output |
|---|---|
| DC voltage | DC voltage measurement on voltage-output instruments |
| Loop supply | 24 V DC transmitter loop power |
| Switch testing | Pressure switch trip point and reset, recorded against applied pressure |
| Signal acquisition | Electrical reading logged simultaneously with pressure, into the same record |
| Electrical accuracy | ±(0.01% RD + 0.003% FS), configuration dependent |
With the module fitted, the TC698A calibration system records both numbers in one pass. Without it the pressure side still calibrates; the mA reading has to be merged by hand afterwards.
Pressure generation does not stretch across six decades in one device. Below atmospheric you are pulling air into a sealed volume; at 160 MPa you are pushing oil through a pressuriser into a thick-walled circuit, and the tubing, seals and fittings belong to a different order of engineering. Every TC698A calibration system is therefore a set of generators, not one wide dial.
What separates one build from another is how those generators are driven. On the TC698A calibration system they are not independent benches sharing a room: one controller sets the target, applies the same stability criterion before accepting the point, and writes into the same certificate. You notice it on the second unit, when two operators run two media on the same afternoon.
| Unit | Range | Medium | Stability | Typical instruments |
|---|---|---|---|---|
| Vacuum | approx. −0.095 to 0 MPa | Air | better than 0.003% F.S. | Vacuum gauges, low-range transmitters and sensors |
| Micro-pressure | approx. −40 to 40 kPa | Air | better than 0.005% F.S. | Draft gauges, differential transmitters, vacuum switches |
| Pneumatic | up to 70 MPa | Air | better than 0.005% F.S. | Gas-side gauges, transmitters and sensors |
| Hydraulic | up to 160 MPa | Transformer oil or hydraulic oil | better than 0.005% F.S. | Hydraulic gauges, high-range transmitters |
| Water | up to 160 MPa | Purified water | better than 0.005% F.S. | Instruments where an oil circuit is not acceptable |
Ranges are those available per unit and are fixed at configuration. The five combine as 2-in-1 through 5-in-1, or as a custom build.
The real comparison is not against a rival automatic system but against the two benches you would otherwise buy. A vacuum bench and a 160 MPa hydraulic bench each carry their own controller, their own stability rule and their own report template. Nothing is wrong with either — the cost is that results from the two are not comparable until someone reconciles them, and reconciliation is manual, so it is the first thing dropped on a busy week.
Where that argument stops holding is a lab that only ever sees one medium. If every instrument is hydraulic and inside one decade, the TC698A calibration system is more machine and more configuration than the job needs. The dedicated benches cover that case directly: the TC668A-Q for vacuum and pneumatic work, the TC668A-Y for hydraulic. Both are single-medium by design and both are simpler to specify.
The list crosses zero and 100 MPa. Configure a 3-in-1 — vacuum, pneumatic, hydraulic. Two benches would cover the same instruments and leave you comparing two reports by eye.
Every instrument is one medium. Do not buy the TC698A calibration system for that. A dedicated bench does the same work with fewer things to specify wrong.
The certificate has to carry a mA reading. Add the electrical module. Without it that number is measured elsewhere and merged later.
You calibrate for other people. Take the 0.01 class and ask for the reference standard’s certificate to travel with the system — the class on your report is only as good as the standard behind it.
Every TC698A calibration system is built to a configuration drawing: the units, the reference standard, the electrical module and the pressure units enabled on the display are fixed before the order is released. Two systems carrying the same model number can therefore differ, so compare drawings when you compare quotations. Four items are worth naming in the quotation rather than assuming — the reference standard and its class, whether the electrical module is included, the adaptor set that matches your instruments’ connections, and a spare seal kit for the medium you will use most.
Documentation
TC698A user guide — daily operation and maintenance
Tell us the instruments and ranges you calibrate, whether you need vacuum, and how many test ports you work with. We reply with a matched configuration, lead time and price — usually within one business day.