TC168T Manual hydraulic power source (-0.085~60) MPa

TC168T manual hydraulic power source

The TC168T benchtop hydraulic power source is a liquid-filled bench: oil or water, three M20 × 1.5 ports, and a two-stage hand pump that holds a set point without a controller. It covers −0.085 to 60 MPa, which is the band where a pneumatic source stops being practical and where most hydraulic gauges, switches and transmitters in service actually sit.

Unlike electric pressure controllers, the TC168T manual hydraulic power source is a hand-driven benchtop pump that needs no power supply. Turning the handwheel builds hydraulic pressure smoothly from vacuum (-0.085 MPa) up to 60 MPa, which makes it a dependable reference source when verifying pressure gauges, transmitters, switches and sensors during incoming inspection, preventive maintenance and NIST-traceable calibration routines.

TC168T benchtop hydraulic power source with dual handwheels and pump unit

Description:

Sixty megapascals is the point where a hand pump stops being a convenience and becomes a decision. Above roughly 10 MPa a pneumatic source turns impractical: air compresses, so every movement of the valve shifts the reading slowly and settling takes minutes rather than seconds. The TC168T uses a liquid column from −0.085 MPa to 60 MPa instead. Pressure follows handwheel travel almost immediately, and a set point stays where it is put.

The pump is split into two stages on purpose. The lever brings the system up to the working band quickly; the screw-type second stage then sweeps the last few megapascals at a rate fine enough to stop on a target instead of sailing past it. A boost valve, a fine-adjustment valve and a return-verification valve sit between the stages, so an operator can approach a point from either direction and confirm that it repeats.

A 60 MPa bench covers the great majority of hydraulic instruments in service: 0–40 and 0–60 MPa gauges, the pressure switches on hydraulic power packs, and the transmitters that sit on those lines. It is not a cut-down version of the 100 MPa bench. The two share the same frame and the same three M20 × 1.5 ports; what differs is handwheel effort at every point above 60 MPa. If the instrument list never goes past 60, the smaller bench is simply faster to use. Where the list does reach 100 MPa, take the TC168T 100 MPa version — the choice is made by the highest instrument on the list, not by budget.
Yuanhuatc advantages banner: 22 years since 2003, ISO 9001 certified, OEM and ODM supported, 30+ countries

Key Features

  • Two-stage hydraulic generation: lever pre-pressurization, screw-type secondary stage
  • Liquid column from −0.085 to 60 MPa — no gas compressibility, so the reading settles at once
  • Boost and fine-adjustment valves for approaching a set point from either direction
  • Return-verification valve, so the same point can be confirmed on the way down
  • Three M20 × 1.5 ports: instrument, reference gauge and a spare, connected at the same time
  • Stainless-steel manifold and corrosion-resistant pump, valves and ports; oil or water as the medium
  • Tool-free quick-connect fittings
  • Hand-driven — no power supply, no motor, nothing on the source itself to calibrate

Applications

Typical work is incoming inspection and periodic verification of hydraulic instruments: 0–40 and 0–60 MPa industrial gauges, pressure switches on hydraulic power packs, and 4–20 mA transmitters that need a five-point check before a certificate is issued. Because the medium is liquid, the bench also suits instruments that should not see air — diaphragm seals, small-volume sensors and anything with a capillary line.

Because the output is set by hand, the bench also suits step-by-step point calibration: the operator can stop at any pressure in the −0.085 to 60 MPa range and hold it while the instrument under test is read, without hunting or overshoot. Nothing is scheduled by software, so an unusual test sequence costs no setup time.

60 MPa or 100 MPa?

Three questions decide it. Does the highest instrument on the list ever exceed 60 MPa? If yes, the 100 MPa bench is the only one that covers it. Are most points below 20 MPa? Then the smaller bench will be quicker for the daily work, and the high end is occasional. Is a 100 MPa reference standard used for everything? If the standard has to be pressurised as well, size the bench for the standard, not the instrument.

Where the TC168T Stops

Two cases are better served elsewhere. If the list mixes sub-1 MPa instruments with high-pressure ones, a liquid bench makes the low points awkward to read, and a pneumatic source is quicker there. If the workload keeps an operator on the handwheel all day, an automatic system removes the handwheel altogether and records the points for you.

For the low end, see the TC166T manual air pressure source. For automated sequences, the TC698A automatic pressure calibration system covers vacuum to 160 MPa without an operator at the wheel.

Leave Your Message